Two phased relays are used as safety signalling relays to evaluate occupancy of a track circuit. Precision and correctness of substantial parameters measurement is an unconditional need for relays use as an important railway safety device.
The measurement assembly is used to measure all basic parameters of signalling relays DSR, DSŠ:Assembly consists of following pieces:
Measurement is carried on the measurement assembly connected to a personal computer. Two-phase power source contains two generators of sinus waveforms with power amplifiers and measurement modules. The measurement modules acquire values of current and voltage on measured coils. The assembly computes both an absolute value and a phase angle. From latter values impedances of coils are computed. It is possible to change the phase angle of generated signals in the range of 0° to 360°. The assembly is equipped by USB interface and EIA/TIA-232. Controlling software allows comfortable control of the power source, input of measurement parameters and acquired data archive. The software also allows printing measurement protocols and labels. Measurement technique is in accordance with ČD T115/1 prescription „Repairs of changeable parts of safety signalling devices.
| Two-phase power source | ||
|---|---|---|
| Supply Voltage | 230V±10%, 50Hz | |
| Output voltage for local coil excitation | 0V÷240V, step 0,5V, | |
| Maximal output current for local coil excitation | 0,25A | |
| Output voltage for rail coil excitation (50Hz, 75Hz) | 0V | 50V, step 0,1V | |
| Maximal output current for rail coil excitation (50Hz, 75Hz) | 0,6A | |
| Output voltage for rail coil excitation (275Hz) | 0V | 200V, step 0,1V | |
| Maximal output current for rail coil excitation (275Hz) | 0,25A | |
| Generated frequencies | 50 Hz, 75 Hz, 275 Hz | |
| Phase angle range | 0° | 360° po 0,1° | |
| Correctness of voltage and current measurement | < 1,0% | |
| Correctness of phase angle measurement | < 1,0° | |
| Resistance measurement range | 10 ÷ 1000 Ω | |
| Correctness of resistance measurement | ±(0,5% *2 + 0,5% *3) | |
| Interface | EIA/TIA-232, USB 2.0 | |
| Power input | 250 VA | |
| Weight | 19,3 kg | |
| Environmental protection | IP20 | |
| Operating temperature range | 5°C | 40°C | |
| Dimensions (w x d x h) | 482 x 430 x 133 mm3 | |
| Stand | ||
| Height of relay (measured from the base) | 280 | 350 mm | |
| Weight | 11 kg | |
| Dimensions (w x d x h) | 280 x 280 x 450 mm3 | |